Print this page.

 

 
AP40

VACUUM DE FILTER SYSTEM





PERFORMANCE SPECIFICATIONS

108,000 GALLONS RECIRCULATED IN 6 HOURS

300 GPM @ 2 GPM FILTER RATE

150 SQUARE FEET FILTER AREA

MAXIMUM BATHING LOAD 60 PERSONS





COMPONENT SPECIFICATIONS

40- 19" ELEMENTS, 3.75 SQ. FEET EACH

7.5 HP VAK PAK IG 7.5 X 7.156  RECIRCULATION PUMP

1 PHASE 230 VOLTS, 300 GPM @ 50 TDH

THROTTLED TO 300 GPM

1.5 HP PENTAIR 34-0039  VACUUM PUMP WITH 5" STRAINER BASKET

SELF PRIMING

4" BLUE WHITE FLOWMETER #CF30400P, 125-500 GPM

VACUUM GAUGE, 0"-30", 2" FACE

THERMOMETER, 32 TO 248 DEGREES

2 VAK PAK SP84  SEPARATION TANK, 84 SQ. FEET.





PIPE SIZES
MAIN DRAIN 8"
GUTTER / SKIMMER 8"
VACUUM LINE 2"
RETURN LINE 4"
FILTER PreCOAT 3"
WASTE LINE 2"
VACUUM TO FILTER 2"
FRESH WATER FILL 1"
FILTER TANK DRAIN 2.5"
RECIRC. SUCTION 6"
HEATER STUBOUTS 3"
TANK OVERFLOW 2”

WATER LEVEL CONTROL STATIC LINE, 1"




CHEMICAL FEEDER OPTIONS

FOR EROSION CL AND LIQUID PH
CLICK DRAWING

AP40-04E


FOR LIQUID CL AND LIQUID PH
CLICK DRAWING
AP40-04L

ELECTRICAL SPECS

AP40-04E


AP40-04L

PUMP CURVE

BOTH MODELS