Print this page.

 

 
AP52D

VACUUM DE FILTER SYSTEM





PERFORMANCE SPECIFICATIONS

140,400 GALLONS RECIRCULATED IN 6 HOURS

390 GPM @ 2 GPM FILTER RATE

195 SQUARE FEET FILTER AREA

MAXIMUM BATHING LOAD 78 PERSONS





COMPONENT SPECIFICATIONS

52- 19" ELEMENTS, 3.75 SQ. FEET EACH

TWO 5 HP PENTAIR I34-5210  RECIRCULATION PUMP

1 PHASE 230 VOLTS, 210 GPM @ 50 TDH EACH

THROTTLED TO 390 GPM

2 HP PENTAIR 34-0040 VACUUM PUMP WITH 5" STRAINER BASKET

SELF PRIMING

6" BLUE WHITE FLOWMETER #CF30600P, 250-1,050 GPM

VACUUM GAUGE, 0"-30", 2" FACE

THERMOMETER, 32 TO 248 DEGREES

3 VAK PAK SP84 SEPARATION TANK, 84 SQ. FEET.





PIPE SIZES
MAIN DRAIN 8"
GUTTER / SKIMMER 8"
VACUUM LINE 2"
RETURN LINE 6"
FILTER PreCOAT 4"
WASTE LINE 2"
VACUUM TO FILTER 2"
FRESH WATER FILL 1"
FILTER TANK DRAIN 2.5"
RECIRC. SUCTION (2) 4"
HEATER STUBOUTS 4"
TANK OVERFLOW 2”

WATER LEVEL CONTROL STATIC LINE, 1"




CHEMICAL FEEDER OPTIONS

FOR EROSION CL AND LIQUID PH
CLICK DRAWING

AP52D-06E


FOR LIQUID CL AND LIQUID PH
CLICK DRAWING
AP52D-06L

ELECTRICAL SPECS

AP52D-06E


AP52D-06L

PUMP CURVE

BOTH MODELS